PLT Probes and Signals

Summary

The PLT-200A Production Line Tool provides several test probes and signals:

  • 8 Power Rails

  • 49 Digital Probes

  • 45 Analog Probes

    • Serial interfaces

      • 1x SWD
      • 1x JTAG
      • 2x UART/SPI
      • 1x CAN

Probes and Signals

PLT-200A Probes and Signals

Power Rails

  • 3V3 (3.3V)
  • 5V (5V)
  • VARV, 12V (2..12V)
  • SWD (3.3V)
  • JTAG (3.3V)
  • UART0, UART1 (3.3V)
PLT-200A Notes Rear ICT Switchboard Voltage Current
3V3 3.3V y y y (Switchboard) y
5V 5V y y y (Switchboard) y
12V/VARV 2..12V y y y (Switchboard) y
SWD_VDD 3.3V y y n n n
JTAG_VCC 3.3V y y n n n
UART0_VDD 3.3V y y n n n
UART1_VDD 3.3V n y n n n
GND GND y y y (Switchboard) n

PLT-200A Power Rails

Analog Signals

Analog Probes

    • 13 Direct Analog Test Probes (DATP00..DATP12)

      • Connected directly from PPC to PLT
      • DATP00..DATP06 can be switched to the MUX0 and MUX1 channels for shorting, impedance or voltage measurements
      • DATP07..DATP12 are connected directly to the DAQ, allowing voltage measurements
      • DATP08 and DATP09 can be connected to the UART0_RXD and UART0_TXD probes), to allow voltage measurements on those lines.
    • 32 Routed Analog Test Probes (RATP00..RATP31)

      • Connected from PPC to PLT through an analog multiplexer on the PPC
      • Only one routed analog test probe from a given ADG bank can be routed at the same time.
      • RATP00..RATP15 are part of the “ADG0 Bank”
      • RATP16..RATP31 are part of the “ADG1 Bank”
      • RATPxx pins can be routed to MUX0 and MUX1 channels for shorting, impedance or voltage measurements
PLT-200A Notes Rear ICT Switchboard Voltage Current
DATP00   n n y (Switchboard) n
DATP01   n n y (Switchboard) n
DATP02   n n y (Switchboard) n
DATP03   n n y (Switchboard) n
DATP04   n n y (Switchboard) n
DATP05   n n y (Switchboard) n
DATP06   n n y (Switchboard) n
DATP07   n n n y n
DATP08 (Alt: UART0_RXD) y y n y n
DATP09 (Alt: UART0_TXD) y y n y n
DATP10   n n n y n
DATP11   n n n y n
DATP12   n n n y n
RATP00 ADG0 Bank n n y (Switchboard) n
RATP01 ADG0 Bank n n y (Switchboard) n
RATP02 ADG0 Bank n n y (Switchboard) n
RATP03 ADG0 Bank n n y (Switchboard) n
RATP04 ADG0 Bank n n y (Switchboard) n
RATP05 ADG0 Bank n n y (Switchboard) n
RATP06 ADG0 Bank n n y (Switchboard) n
RATP07 ADG0 Bank n n y (Switchboard) n
RATP08 ADG0 Bank n n y (Switchboard) n
RATP09 ADG0 Bank n n y (Switchboard) n
RATP10 ADG0 Bank n n y (Switchboard) n
RATP11 ADG0 Bank n n y (Switchboard) n
RATP12 ADG0 Bank n n y (Switchboard) n
RATP13 ADG0 Bank n n y (Switchboard) n
RATP14 ADG0 Bank n n y (Switchboard) n
RATP15 ADG0 Bank n n y (Switchboard) n
RATP16 ADG1 Bank n n y (Switchboard) n
RATP17 ADG1 Bank n n y (Switchboard) n
RATP18 ADG1 Bank n n y (Switchboard) n
RATP19 ADG1 Bank n n y (Switchboard) n
RATP20 ADG1 Bank n n y (Switchboard) n
RATP21 ADG1 Bank n n y (Switchboard) n
RATP22 ADG1 Bank n n y (Switchboard) n
RATP23 ADG1 Bank n n y (Switchboard) n
RATP24 ADG1 Bank n n y (Switchboard) n
RATP25 ADG1 Bank n n y (Switchboard) n
RATP26 ADG1 Bank n n y (Switchboard) n
RATP27 ADG1 Bank n n y (Switchboard) n
RATP28 ADG1 Bank n n y (Switchboard) n
RATP29 ADG1 Bank n n y (Switchboard) n
RATP30 ADG1 Bank n n y (Switchboard) n
RATP31 ADG1 Bank n n y (Switchboard) n

PLT-200A Analog Test Probes

Digital Signals

PLT-200A Digital Signals

Digital Probes

    • 17 Direct Digital Test Probes (DDTP00..DDTP16)

      • Connected directly from PPC to PLT
      • DDTP00..DDTP08 can be switched to the MUX2 and MUX3 channels for shorting
      • Can be configured as inputs (no pull-up) or outputs (low or high)
      • Can sense logic state for probes that are configured as inputs
      • DDTP15 and DDTP16 can be connected to the UART0_CTS and UART0_RTS probes, to allow digital sensing or control of those lines.
    • 32 Routed Digital Test Probes (RDTP00..RDTP31)

      • Connected from PPC to PLT through a multiplexer on the PPC
      • Can be configured as inputs (with or without pull-up) or outputs (low or high)
      • Can sense logic state for probes that are configured as inputs
PLT-200A Notes Rear ICT Switchboard Voltage Current
DDTP00   n y y (Switchboard) n
DDTP01   n y y (Switchboard) n
DDTP02   n y y (Switchboard) n
DDTP03   n y y (Switchboard) n
DDTP04   n y y (Switchboard) n
DDTP05   n y y (Switchboard) n
DDTP06   n y y (Switchboard) n
DDTP07   n y y (Switchboard) n
DDTP08   n y y (Switchboard) n
DDTP09   n y n n n
DDTP10   n y n n n
DDTP11   n y n n n
DDTP12   n y n n n
DDTP13   n y n n n
DDTP14   n y n n n
DDTP15 (Alt: UART0_CTS) y y n n n
DDTP16 (Alt: UART0_RTS) y y n n n
RDTP00   n y n n n
RDTP01   n y n n n
RDTP02   n y n n n
RDTP03   n y n n n
RDTP04   n y n n n
RDTP05   n y n n n
RDTP06   n y n n n
RDTP07   n y n n n
RDTP08   n y n n n
RDTP09   n y n n n
RDTP10   n y n n n
RDTP11   n n n n n
RDTP12   n n n n n
RDTP13   n n n n n
RDTP14   n n n n n
RDTP15   n n n n n
RDTP16   n n n n n
RDTP17   n n n n n
RDTP18   n n n n n
RDTP19   n n n n n
RDTP20   n n n n n
RDTP21   n n n n n
RDTP22   n n n n n
RDTP23   n n n n n
RDTP24   n n n n n
RDTP25   n n n n n
RDTP26   n n n n n
RDTP27   n n n n n
RDTP28   n n n n n
RDTP29   n n n n n
RDTP30   n n n n n
RDTP31   n n n n n

PLT-200A Digital Test Probes

Clock Signals

  • CLK0, CLK1
PLT-200A Notes Rear ICT Switchboard Voltage Current
CLK0   n n n n n
CLK1   n n n n n

PLT-200A Clock Signals

Serial Interfaces

  • UART0, UART1
  • SWD
  • JTAG
  • CAN
PLT-200A Notes Rear ICT Switchboard Voltage Current
UART0_TXD (Alt: DATP09) y y n (Alt: DATP09) n
UART0_RXD (Alt: DATP08) y y n (Alt: DATP08) n
UART0_CTS (Alt: DDTP15) y y n n n
UART0_RTS (Alt: DDTP16) y y n n n
UART1_TXD   n y n n n
UART1_RXD   n y n n n
UART1_CTS   n y n n n
UART1_RTS   n y n n n
SWD_NRST   y y n n n
SWD_SWDIO   y y n n n
SWD_SWCLK   y y n n n
SWD_SWO   y y n n n
JTAG_TMS   y y n n n
JTAG_TCK   y y n n n
JTAG_TDO   y y n n n
JTAG_TDI   y y n n n
JTAG_TRST   y y n n n
CAN_L   n y n n n
CAN_H   n y n n n

PLT-200A Serial Interface Signals

Switchboard

PLT-200A Switchboard

The mux command can be used to assign any of the following signals to one of 4 multiplex channels.

signal MUX Description
DATP00..DATP06 0, 1 Direct Analog Test Probes
RATP00..RATP31 0, 1 Routed Analog Test Probes
DDTP00..DDTP08 2, 3 Direct Digital Test Probes
RVREF all Impedance measurement, reference voltage
RA all Impedance measurement, test voltage
GND all Ground
3V3OUT all 3.3V power rail
5VOUT all 5.0V power rail
VARVDIV all VARV power rail, after 1/3 voltage divider

Relays between the different multiplex channels can be controlled using the short command.

suite:
- ident: ICT-T1
  title: Setup MUX
  steps:
  - command: mux 0 DATP02
  - command: mux 1 DATP03
  - command: mux 2 RA
  - command: mux 3 RVREF
  - command: short 0 2 set
  - command: short 1 3 set
- ident: ICT-T2
  title: Measure impedance DATP02..DATP03
  steps:
  - command: measure impedance 10-200kOhm