PLT-OS v1.4¶
PLT-OS v1.4.31¶
Bugs fixed:
LYJ-652: Fix label print test if no test plan is loaded
New features:
LYJ-647: Program Microchip PIC18
Changes:
LYJ-648: Inform user when report submission fails
LYJ-650: Attempt to determine ip address without outbound connection
PLT-OS v1.4.30¶
Changes:
Check for time synchronization before starting AWS IoT connection
PLT-OS v1.4.29¶
New features:
LYJ-644: Add support for programming SiLabs EFM32 target (untested)
Changes:
LYJ-645: Always include value for failing test steps
PLT-OS v1.4.28¶
Changes:
Fix reset from PLTcloud
PLT-OS v1.4.27¶
Changes:
Support webhook and serial requests when in debug mode
BLE library stability improvements
PLT-OS v1.4.26¶
Changes:
Reset DDTPxx GPIO state before and after every test run
program
: Add support for ATmega328PB target (untested)
PLT-OS v1.4.25¶
Changes:
Revert to human-readable measurement values in PDF & CSV reports
PLT-OS v1.4.24¶
Bug fixes:
LYJ-626: Fix current measurement calculation. This change affects current measurements by a factor of 0.41675
Changes:
LYJ-629: Default MUXes to GND
PLT-OS v1.4.23¶
New features:
LYJ-624, LYJ-625:
eval
command:numeric(..)
function to convert strings and measurement results to numeric values
PLT-OS v1.4.22¶
Bug fixes:
LYJ-622: reset MUX, switch and relay state after test run
PLT-OS v1.4.21¶
New features:
LYJ-613:
program
: Finalize support for EFR32 target (tested)
PLT-OS v1.4.20¶
Changes:
LYJ-613:
program
: Add support for EFR32 target (untested)
PLT-OS v1.4.19¶
Bug fixes:
LYJ-607: Prevent continuous restarts of IoT connections
Changes:
LYJ-613: openocd_zephyr: Add config files for EFR32 target
PLT-OS v1.4.18¶
Bug fixes:
LYJ-612: Fix LabJack USB failures
New features:
LYJ-609: Support programming Cypress PSoC4
PLT-OS v1.4.17¶
(no change)
PLT-OS v1.4.16¶
New features:
LYJ-608: Calibration offsets in test plan
PLT-OS v1.4.15¶
Bug fixes:
LYJ-606: Prevent crash when LPC-Link2 is attached
PLT-OS v1.4.14¶
New Features:
LYJ-609: Preliminary support for Cypress PSoC4
PLT-OS v1.4.13¶
New Features:
LYJ-591: Support image writing from PLT-200
LYJ-604: Support cmsis target for CMSIS Pack-based
program
anderase
PLT-OS v1.4.12¶
Changes:
LYJ-602: Preliminary support for CMSIS-DAP programming
PLT-OS v1.4.11¶
New Features:
LYJ-597: Add LPC11xx_DAP and LPC11xx_JLink targets
LYJ-599:
openocd
command with raw OpenOCD commands
Changes:
Update to ly10-system-rpi3 v0.9.11
PLT-OS v1.4.10¶
Changes:
Update to ly10-system-rpi3 v0.9.10
PLT-OS v1.4.9¶
Bug fixes:
LYJ-595: Fix issue with startup when scanner attached
Changes:
LYJ-590: Use Cypress-specific openocd
PLT-OS v1.4.8¶
New features:
serial set
command
Changes:
Add PSoC6, PSoC6_KP3 targets (untested)
Add ATMega128_ISP target (untested)
PLT-OS v1.4.7¶
Changes:
Change default NTP pool
PLT-OS v1.4.6¶
New features:
pin
command: control SWD_NRST output level
PLT-OS v1.4.5¶
Changes:
Update to pltrunner v1.3.4: minor bug fixes
PLT-OS v1.4.4¶
New features:
Pre-populate
PLT_SN
key with PLT serial number
PLT-OS v1.4.3¶
Changes:
Remove flag for carrier ID
PLT-OS v1.4.2¶
New features:
Generate testID if no
Ident:
was specified in the test planPrefix item identifier with
identPrefix:
specified in test plan
Changes:
printer: Read status
PLT-OS v1.4.1¶
New features:
Test plan progress bar
Changes:
Update to ly10-system-rpi3 v0.9.8
PLT-OS v1.4.0¶
New features:
webhook request
: generic variant of serial request that does not require a serial number to be returned.Pre-calculate checksum for LPC11xx firmware images
“Printer Reset” function, available from OLED menu
Removed:
Support for ESP32_HomeKit target has been removed (ESP32_UART and ESP32_JTAG targets are still supported)
Changes:
Show “PLT-OS” instead of “System” during PLT-OS update
program
command: Accept any number of firmware elementsmeasure results are now propagated in full into TestReport JSON